TerraBrain

What did an engineer specify for a previously piered Sand Springs house?

Reviewed by Preston, Oklahoma foundation repair consultant ยท Updated 2026-10-14

Sand Springs20252-story wood frame, brick veneer; garage addition and a former garage converted to living spaceslab-on-grade with continuous perimeter footings (floating floor slab)

In short: A two-story brick-veneer house in Sand Springs had brick cracks on three sides, a chimney separating from the walls and cracks throughout the interior. It had been piered before, with no records available 1. The engineer attributed the movement to active clay, insufficient earlier piering, and differential movement between the original house and its additions. The scope was 21 perimeter steel piers, 10 to 15 interior helical piers with foam injection, and plumbing and duct checks 1.

What did the house show?

The engineer inspected the house in May 2025 1. It is a two-story wood-frame house with brick veneer. The garage is an addition, and a former garage was converted to living space. The foundation is a slab-on-grade with continuous perimeter footings and a floating floor slab 1.

Observed conditions 1:

What did the engineer find was causing it?

The engineer named three factors 1:

What repair was specified?

Perimeter (item 1). 21 perimeter piers, shown at 9 ft dimensions on the plan, with equal spacing where none is given 1. The engineer's pier specification requires 1:

Locations and count may change for footing conditions 1.

Interior (item 2). Helical piers under load-bearing walls, about 6 ft on center, with foam injection elsewhere on a roughly 6 ft port grid. The foam is to be warranted. The engineer estimated 10 to 15 interior piers, with cracks stitched at 18 in. 1.

Other items. A plumbing test before and after the work, a camera inspection of the in-slab ducts, and replacement of fiberboard attic flooring with plywood or OSB 1.

What does this case show about Oklahoma foundations?

Free, plain-English answers. It asks a few questions and walks you to the repair that fits.

Common questions

What is a pier log?

A record the engineer required for every pier: depth, pier type, diameter, driving pressure and amount of lift.

Why are additions expected to move separately?

The engineer noted that the garage and converted room were additions, so independent movement at the joints with the original house is expected.

Why use helical piers inside and steel piers outside?

The engineer specified steel push piers under the perimeter footings and helical piers under interior load-bearing walls, with foam injection elsewhere under the slab.

Sources

  1. Engineer's evaluation report, 2025 (private client report) Licensed professional engineer, Oklahoma
  2. An Occurrence and Distribution Survey of Expansive Materials in the United States by Physiographic Areas (FHWA-RD-76-82) U.S. Federal Highway Administration
  3. Living With Shrink/Swell Soils: A Homeowners' Guide to Maintenance of Shallow Foundations ASCE Geo-Institute, Shallow Foundations Committee